What is the difference between an expansion tank and a hydraulic accumulator?

Home / Heating

Back

Published: 12/18/2020

Reading time: 3 min

0

1297

The question of what is the difference between a hydraulic accumulator and an expansion tank remains unclear to some consumers, although such equipment has been used in boiler houses for quite a long time.

Water supply and heating systems cannot be imagined without such successful additions; most people are accustomed to distinguishing these devices by their shade.

One of the units is available in blue, and the other in red, but their structure has its own nuances. I want to analyze in detail the differences between the devices and describe the purpose of installing each type of device.

  • 1 Design and purpose of the expansion tank
  • 2 Design and purpose of the hydraulic accumulator
  • 3 What are the differences 3.1 How does the expansion tank work
  • 3.2 How a hydraulic accumulator works
  • 4 Is it possible to use a hydraulic accumulator as an expansion tank
  • What is the difference between a hydraulic accumulator and an expansion tank?

    Tanks used in heating or hot water supply systems are more correctly called expansion tanks.

    Hydraulic accumulators, in turn, are used in cold water supply systems.

    In this case, a heating tank is needed to reduce the pressure resulting from the thermal expansion of water, and in the water supply, on the contrary, to increase it and raise the weak pressure to a comfortable value. In other words, their task is to somehow maintain the desired pressure of the working environment.

    In both cases, pressure regulation is carried out using an elastic membrane and an air chamber in which the gas is under pressure and tends to fill the entire volume of the housing. The type of this membrane is also one of the differences between expansion tanks and hydraulic accumulators.

    Differences between tanks by type of membrane

    Tanks can have one of two types of membrane: pear-shaped or diaphragm. It is important to distinguish between them since using a tank with an unsuitable design significantly reduces its service life.

    The diaphragm (disc-shaped) membrane cuts the body in half and does not isolate the coolant from the metal body. Membranes of this type do not tolerate proximity to the pump and cannot be repaired if they fail. When they break, the entire tank must be replaced, but on the other hand, they are cheaper and, if used correctly, last longer, since the diaphragm distributes the load of the working environment more evenly.

    The pear-shaped membrane is attractive primarily because it can be replaced independently if it fails. However, due to its shape and fastening, the load on the membrane is distributed unevenly, which is an additional wear factor. It is mounted inside the housing using a special holder and fixed with a flange.

    Moreover, this type of membrane can be used both in a hydraulic accumulator and in the design of an expansion tank. But the requirements for them are different. For the first, the suitability of the membrane material for drinking water is important. For the second, it is important to maintain the required temperature of the working environment.

    Installation, testing, connection

    Simply installing a hydraulic tank is not a difficult task - the more pressing problem is usually the correct choice of volume and operating pressure, so it is better if all the work is carried out by specialists.

    First of all, a location for installation is selected, which must meet the following requirements:

    • vibration and noise from operating equipment do not disturb residents,
    • there is sufficient space for maintenance and repair of the hydraulic tank,
    • reliable support is ensured on a flat and strictly horizontal base.

    During installation, shock-absorbing rubber pads are used, which partially dampen vibration.


    To install the hydraulic tank, you need a reliable foundation Source de.decorexpro.com

    The hydraulic accumulator is connected to the water supply system in the following order:

    • A level area is prepared on a solid foundation, such as a concrete basement floor.
    • The hydraulic tank is installed on the base using special gaskets.
    • Control measurements of pressure in the cylinder are carried out in a non-working state. It must be at least 1.5 bar (atm). This is the factory setting. If the pressure is insufficient, you can use a car pump.
    • A fitting with five outlets is installed on the accumulator pipe.
    • The water pump, water pipe, pressure gauge and pressure switch are connected one by one to the outlets of the fitting.

    To reduce vibration, flexible adapters are used. They are installed in the area where the unit is connected to the water supply. Make sure that the adapter's clearance is not less than the diameter of the connected pipe.

    What is a hydraulic accumulator?

    From the name of the hydraulic accumulator you can guess that it is used primarily to store water, but it also performs other functions. For example, it dampens water hammer and smoothes out pressure fluctuations that occur during pump operation. In addition, it reduces the number of pump starts, which can significantly extend its life.

    The operating cycle of the accumulator is simple: the pump pumps water into it and turns off when the pressure on the relay reaches the maximum permissible value. The next turn on of the pump occurs when, as a result of water intake, the pressure on the relay drops to the value set as the minimum.

    It is important to note: since drinking water is used as the working medium in such a system, it should not come into contact with metal parts of the housing, which may rust.

    In addition, the membrane in the accumulator must be more wear-resistant than in the expansion tank due to significantly more intense deformation and close placement of the pump.

    Video description

    Connecting the pump to the hydraulic tank is shown in the video:

    • The hydraulic tank is filled with water and checked for leaks. If necessary, additional sealing of threaded connections is carried out.

    Water must be poured into the tank very slowly to avoid rupture of the membrane. During long-term storage, the “pear” may stick together; with gradual filling, the flexible form will smoothly straighten out.

    • The power supply is connected and the pressure switch is adjusted according to the instructions for the equipment.

    When using a submersible pump, a check valve must be installed. It prevents water from flowing back into the well.


    Connection diagram of the hydraulic accumulator to the elements of the water supply network Source gkyzyl.ru

    What is an expansion tank in a heating system?

    Its name also speaks for itself; it is designed to compensate for the thermal expansion of water in hot water supply and heating systems . The absence of an expansion tank in closed systems would inevitably lead to exceeding the maximum permissible pressure and leaks even with a slight increase in temperature.

    If water with a temperature of 0 °C is heated to 100 °C, its density will become less, causing its volume to increase by about 4.3%. Without taking into account the deformation of pipes and other elements of the system, an increase in temperature by one degree increases the pressure by 3 bar.

    The expansion tank must be able to operate in high temperature conditions. In addition, it must be of sufficient size to accommodate all excess coolant volume. As a rule, this is about 15-20% of the total coolant volume at room temperature.

    What is the difference between a blue expansion tank and a red one?

    Often, by the red or blue color of the tank, you can determine whether it is designed to work with a cold or hot working environment. However, the color of the tank depends solely on the preferences of the manufacturer and can be anything. For example, in Arma Shop we sell ProTank tanks (Turkey), painted gray. They are universal and can be used both as expansion tanks and hydraulic accumulators.

    Models with bodies of various volumes are available for purchase: from 2 to 10,000 liters. If necessary, you can choose a model with a pump platform and a pressure gauge. Tanks are also available in vertical or horizontal mounting position.

    Why you need to know how to select a hydraulic tank

    In order for the equipment to function well and provide water to the residents of the house, you need not only to know what a hydraulic accumulator is for water supply systems, but also how to choose it correctly.

    If the storage volume is insufficient, the pump will work in enhanced mode in order to provide the necessary pressure in the network.

    If the volume of the hydraulic tank is excessive, there will be no such problem; in addition, there will always be a certain amount of water in the tank, which can be used, for example, in the event of a power outage. But you shouldn’t chase the size, because the main purpose of the equipment is to maintain pressure to distribute liquid in the network. And to store water, you can choose another, less expensive tank, for example, made of plastic.


    Each thing has its own purpose - an ordinary plastic container is better suited for storing water “in reserve” Source gidrosnab.ru

    Let's sum it up

    Hydraulic accumulators and expansion tanks have different purposes, but belong to a common group - expansion tanks. What to choose specifically in your case? First you need to evaluate the entire system and decide what function this device should perform. If you need a pressure tank for drinking water, you should use a hydraulic accumulator with a pear-shaped membrane.

    If it is necessary to compensate for the expansion of the coolant in the heating system, then use a membrane expansion tank (expanzomat), in which the diaphragm is designed to operate at high temperatures.
    ☛ Select expansion tank

    Popular models

    When purchasing a hydraulic accumulator, the buyer pays main attention to the volume of the cylinder. Today, models with a capacity from 10 liters to 200 liters are produced and used in everyday life.

    According to a survey of the Russian Internet audience, the most popular are hydraulic tanks with a volume of 76-100 l, 11-25 l and 26-50. For summer cottages, storage tanks of up to 10 liters are often purchased. Vertical installation is a priority.

    Usually, which hydraulic accumulator to buy for water supply systems is chosen simply based on the price-quality ratio. Manufacturers offer models that combine various components and decent quality at a reasonable price. The ranking of manufacturers is as follows: Reflex, Jeelex, Wester, UNIPUMP, CIMM.

    Recommendations for installation and operation

    Installing a hydraulic tank is easy; it is simply connected to the water supply system after the pump. Before entering the device, you need to install a good filter to clean the water from impurities. They can accumulate inside and damage the membrane.


    A hydraulic accumulator designed for autonomous water supply is best used with a pressure switch that will control the operation of a submersible pump

    You need to choose the right place for installation. The HA should be placed where one can freely approach to inspect the device and maintain it. Over time, the device may need to be repaired, so it doesn’t hurt to think in advance about the procedure for dismantling it and the difficulties that may arise at this time.

    It is very important that the dimensions of the pipe and the water pipe match. This will avoid hydraulic losses due to narrowing of the route in some area. The use of adapters is acceptable, but not recommended. As water flows in and out, the membrane tank may vibrate.

    It is recommended to attach it to the base using shock-absorbing pads. Connection to the water supply is made with a flexible liner. You should make sure that the device is correctly aligned horizontally and vertically; distortions are not allowed.

    It is necessary to take care in advance about the possibility of disconnecting the HA from the water supply so that you do not have to completely drain the water from the system. This requirement is met by installing a conventional shut-off valve. For small containers with a capacity of up to 10 liters, which do not have a nipple, it is also necessary to provide for the installation of a drain valve.

    You can read more about how to connect a hydraulic accumulator to a water supply system in this material.

    Maintenance of the hydraulic tank comes down to a careful inspection of the housing and monitoring the pressure in the air compartment. Sometimes you need to pump up the air or bleed it to restore the correct performance. Typically the pressure should be about two atmospheres or slightly less. In addition, the air that has accumulated behind the membrane in the compartment where the water is stored should be removed.

    Sometimes you can even install an automatic air vent here. If there is no hole for this procedure, you need to disconnect the HA from the water supply and completely empty it through the drain tap. The air will come out of the container along with the water. Then you just have to turn on the pump again so that water starts flowing into the tank again.

    Speaking about how a membrane accumulator works, it is worth noting that the most common failure in a hydraulic accumulator is a membrane rupture. This elastic element is subject to constant tension and compression, and therefore fails over time.

    Here are the signs that the membrane has ruptured:

    • water comes from the tap in sharp bursts;
    • the pressure gauge needle “jumps”;
    • After the contents of the “air” compartment are completely bled, water flows out of the nipple.

    The last point allows you to accurately determine whether the problem is really with the membrane. If water does not flow out of the nipple, and water enters the system poorly, most likely the housing is depressurized. You need to carefully examine it, find and repair the cracks.


    The membrane can deteriorate due to wear or improper use. It needs to be completely replaced; repairing this element is useless

    Replacing the membrane is not difficult, but you need to select exactly the same element as the damaged one, since it is designed specifically for this particular HA.

    To carry out repairs, you need:

    1. Disconnect the device from the water supply system.
    2. Drain the water, bleed the air.
    3. Unscrew the mounting screws.
    4. Remove the damaged membrane.
    5. Install the correct element.
    6. Secure it with screws.
    7. Install the GA in place and connect it to the system.

    The most difficult part of this procedure is tightening the screws. It should be uniform, so it is recommended to twist them, making one turn on each element in turn. This tactic will allow you to properly secure the membrane to the body and prevent its edge from sliding inward.

    Some inexperienced craftsmen, in an effort to improve the quality of the connection, apply sealant to the edge of the membrane. This should not be done, since the composition can destroy the rubber and cause the opposite effect.

    Rating